Using simulation to explore the impact of device design on the learning and performance of peripheral intravenous cannulation

Posted on 2019-11-22 - 06:00
Abstract Background The design of medical devices impacts upon the performance of healthcare professionals and patient safety. However, multiple devices serving the same function are often available. The purpose of this study was to use simulation as a means of examining the impact of differences in device design on (1) learning of, or attainment of behavioral fluency in, peripheral intravenous cannulation (PIVC); and (2) the generalization, or transfer, of learning on one device to performance of PIVC using an untrained device. Methods A total of 25 final cycle medical students participated in this study which used a randomized two-group design. Participants were randomly assigned to learn PIVC using either a closed PIVC device (a single device which consists of an intravenous cannula with a pre-attached extension tube; n = 14) or an open PIVC device (a two-piece device made up of an intravenous cannula and a separate extension tube which is attached following insertion of the cannula; n = 11). Task analyses were developed for the performance of PIVC using each device. Subsequently, simulation-based fluency training was delivered to both groups using their assigned PIVC device, and continued for each participant until the fluency criterion was achieved. Following achievement of fluency, participants were asked to perform PIVC using the untrained device (i.e., the PIVC device that they had not been trained on). Results All participants in both groups met the fluency criterion, and no significant differences were observed in the number of trials or total training required by groups to achieve fluency. Participants in both groups improved significantly from baseline (M = 11.69) to final training trial (M = 100). However, a significant decrement in performance (M = 81.5) was observed when participants were required to perform PIVC using the untrained device. Conclusions Participants achieved fluency in PIVC regardless of the device used. However, significant decrements in performance were observed when participants were required to perform PIVC using a novel device. This finding supports the need for careful consideration of devices purchased and supplied in the clinical setting, and the need for training prior to the introduction of novel devices or for new staff members.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?