Springer Nature
Browse

The utility of multi-stack alignment and 3D longitudinal image registration to assess bone remodeling in rheumatoid arthritis patients from second generation HR-pQCT scans

Posted on 2020-04-08 - 09:09
Abstract Background Medical imaging plays an important role in determining the progression of joint damage in rheumatoid arthritis (RA). High resolution peripheral quantitative computed tomography (HR-pQCT) is a sensitive tool capable of evaluating bone microarchitecture and erosions, and 3D rigid image registration can be used to visualize and quantify bone remodeling over time. However, patient motion during image acquisition can cause a “stack shift” artifact resulting in loss of information and reducing the number of erosions that can be analyzed using HR-pQCT. The purpose of this study was to use image registration to improve the number of useable HR-pQCT scans and to apply image-based bone remodeling assessment to the metacarpophalangeal (MCP) joints of RA patients. Methods Ten participants with RA completed HR-pQCT scans of the 2nd and 3rd MCP joints at enrolment to the study and at a 6-month follow-up interval. At 6-months, an additional repeat scan was acquired to evaluate reliability. HR-pQCT images were acquired in three individual 1 cm acquisitions (stacks) with a 25% overlap. We completed analysis first using standard evaluation methods, and second with multi-stack registration. We assessed whether additional erosions could be evaluated after multi-stack registration. Bone remodeling analysis was completed using registration and transformation of baseline and follow-up images. We calculated the bone formation and resorption volume fractions with 6-month follow-up, and same-day repositioning as a negative control. Results 13/57 (23%) of erosions could not be analyzed from raw images due to a stack shift artifact. All erosions could be volumetrically assessed after multi-stack registration. We observed that there was a median bone formation fraction of 2.1% and resorption fraction of 3.8% in RA patients over the course of 6 months. In contrast to the same-day rescan negative control, we observed median bone formation and resorption fractions of 0%. Conclusions Multi-stack image registration is a useful tool to improve the number of useable scans when analyzing erosions using HR-pQCT. Further, image registration can be used to longitudinally assess bone remodeling. These methods could be implemented in future studies to provide important pathophysiological information on the progression of bone damage.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?