Springer Nature
Browse

The median effective dose (ED50) of cis-Atracurium for laryngeal mask airway insertion during general Anaesthesia for patients undergoing urinary surgery

Posted on 2020-03-20 - 04:57
Abstract Background In clinical practice, the laryngeal mask airway is an easy-to-use supraglottic airway device. However, the cis-atracurium dosage for laryngeal mask insertion has not been standardised. We aimed to determine the optimal dose of cis-atracurium using a sequential method for successful laryngeal mask insertion. Methods The cohort study protocol is registered at clinicaltrial.gov (NCT-03668262). Twenty-three patients undergoing elective urinary surgery were sequentially administered cis-atracurium doses as follows: 150, 100, 70, 50, 30, and 20 μg·kg− 1. The main outcome involved the determination of the response to laryngeal mask airway insertion: ≥16 points and < 16 points indicated “satisfactory” and “unsatisfactory” responses, respectively. The median effective dose was estimated using the mean of the seven crossovers from “satisfactory” and “unsatisfactory” responses. The primary outcome involved the determination of the median effective dose (ED50) of cis-atracurium for laryngeal mask airway insertion. Results The median effective dose of cis-atracurium was 26.5 μg·kg− 1 (95% CI 23.6–29.8) using the sequential method. Heart rate was decreased in the 50 μg·kg− 1 group compared to that in the 30 μg·kg− 1 group at timepoints T7, T8, and T10 (P = 0.0482, P = 0.0460, and P = 0.0236, respectively), but no difference was observed in the 20 μg·kg− 1 group. Systolic blood pressure was decreased in the 50 μg·kg− 1 group compared to that in the 20 μg·kg− 1 group at timepoints T2, T3, and T4 (P = 0.0159, P = 0.0233, and P = 0.0428, respectively). The train-of-four value was significantly lower in the 50 μg·kg− 1 group than in the 30 μg·kg− 1 group at timepoint T3 (P = 0.0326). Conclusions The ED50 of cis-atracurium was 26.5 μg·kg− 1 for laryngeal mask airway insertion. Trial registration Clinicaltrial.gov Registry, NCT03668262, Registered on 11 September 2018.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?