Springer Nature
Browse

Szabo 2-stent technique for coronary bifurcation lesions: procedural and short-term outcomes

Posted on 2020-07-08 - 04:24
Abstract Background Provisional 1-stent technique is currently regarded as the default approach for the majority of bifurcation lesions. Nonetheless, 2-stent techniques may be required for complex bifurcations with high compromise risk or fatal consequences of side branch (SB) occlusion. Limitations exist in current approaches, as stents gap, multiple metal layers and stent malapposition caused by imprecise placement with fluoroscopic guide and intrinsic technical defects. This study was designed to investigate the effectiveness of the novel Szabo 2-stent technique for coronary bifurcation lesions. Methods In the Szabo 2-stent technique, one stent is precisely implanted at the SB ostium with Szabo technique resulting in a single strut protruding into the main vessel (MV). After MV rewiring and SB guidewire withdrawal, another stent is implanted in MV followed by proximal optimization technique, SB rewiring, and final kissing inflation (FKI). Results The technique tested successfully in silicone tubes (n = 9) with: procedure duration, 31.2 ± 6.8 min; MV and SB rewiring time, 26.8 ± 11.2 s and 33.3 ± 15 s; easy FKI; and 2.3 ± 0.5 balloons/procedure. Bifurcation lesions (n = 22) were treated with angiographic success in MV and SB, respectively: increased minimal lumen diameter (0.63 ± 0.32 mm to 3.20 ± 0.35 mm; 0.49 ± 0.37 mm to 2.67 ± 0.25 mm); low residual stenosis (12.4 ± 2.4%; 12.4 ± 2.3%); and intravascular ultrasound confirmed (n = 19) full coverage; minimal overlap and malapposition; minimal lumen area (2.4 ± 1.2 mm2; 2.1 ± 1.0 mm2); plaque burden (78.1 ± 11.3%; 71.6 ± 15.5%); and minimal stent area (9.1 ± 1.6 mm2; 6.1 ± 1.3 mm2). Periprocedural cardiac troponin increased in 1 asymptomatic patient without electrocardiographic change. There was no target lesion failure (cardiac death, myocardial infarction, target lesion revascularization) at 6-month follow-up. Conclusions The Szabo 2-stent technique for bifurcation lesions provided acceptable safety and efficacy at short-term follow-up.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?