Springer Nature
Browse

Radiomic features from MRI distinguish myxomas from myxofibrosarcomas

Posted on 2019-08-16 - 03:41
Abstract Background Myxoid tumors pose diagnostic challenges for radiologists and pathologists. All myxoid tumors can be differentiated from each other using fluorescent in-situ hybridization (FISH) or immunohistochemical markers, except for myxomas and myxofibrosarcomas. Myxomas and myxofibrosarcomas are rare tumors. Myxomas are benign and histologically bland, whereas myxofibrosarcomas are malignant and histologically heterogenous. Because of the histological heterogeneity, low grade myxofibrosarcomas may be mistaken for myxomas on core needle biopsies. We evaluated the performance of T1-weighted signal intensity (T1SI), tumor volume, and radiomic features extracted from magnetic resonance imaging (MRI) to differentiate myxomas from myxofibrosarcomas. Methods The MRIs of 56 patients (29 with myxomas, 27 with myxofibrosarcomas) were analyzed. We extracted 89 radiomic features. Random forests based classifiers using the T1SI, volume features, and radiomic features were used to differentiate myxomas from myxofibrosarcomas. The classifiers were validated using a leave-one-out cross-validation. The performances of the classifiers were then compared. Results Myxomas had lower normalized T1SI than myxofibrosaromas (p = 0.006) and the AUC using the T1SI was 0.713. However, the classification model using radiomic features had an AUC of 0.885 (accuracy = 0.839, sensitivity = 0.852, specificity = 0.828), and outperformed the classification models using T1SI (AUC = 0.713) and tumor volume (AUC = 0.838). The classification model using radiomic features was significantly better than the classifier using T1SI values (p = 0.039). Conclusions Myxofibrosarcomas are on average higher in T1-weighted signal intensity than myxomas. Myxofibrosarcomas are larger and have shape differences compared to myxomas. Radiomic features performed best for differentiating myxomas from myxofibrosarcomas compared to T1-weighted signal intensity and tumor volume features.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?