Springer Nature
Browse

Prospective multicentre validation study of a new standardised version of the 400-point hand assessment

Posted on 2020-05-21 - 03:47
Abstract Background Hand rehabilitation needs valid evaluation tools; the 400-point Hand Assessment (HA) is an exhaustive but not standardised tool. The aim of this study was to validate a standardised version of this test. Methods A modified version and a standardised prototype was made for this prospective validation study (four centres, three countries). Psychometric properties studied: reliability (intra-rater and inter-rater, standard error of measurement [SEM], minimum detectable change [MDC],internal consistency); content validity, construct validity with Jebsen Taylor hand function test, QuickDASH, MOS-SF 36 and pain; responsiveness, using an anchor-based approach (ROC curve with area under curve, mean response change) with calculation of MCID. For SEM, MDC and responsiveness, QuickDASH was used for comparison. Results One hundred and seventy-six patients with hand/wrist injuries were included between May 2013 and February 2015. One hundred and seventy were available for final analysis: 67% men; mean age 43.4 ± 13.2 years; both manual and office workers (46, 5% of each); 37% had a hand or wrist fracture. Reliability: ICC intra-rater = 0.967 [0.938–0.982]; inter-rater = 0.868 [0.754–0.932]. Distribution-based approach: for 400-point HA/QuickDASH: SEM = 3.48/4.52, MDC = 9.065/12.53, internal consistency of 400-point HA: Cronbach α = 0.886. Validity: Content validity was good according to COSMIN guidelines. Construct validity: correlation coefficient: Jebsen-Taylor hand function test = − 0.573 [− 0.666–0.464], QuickDASH = − 0.432 at T0 [− 0.545–0.303], − 0.551 at T3 [− 0.648–0.436]; MOS-SF 36 physical component = 0.395 [0.263–0.513]; no correlation with MOS-SF 36 mental component = 0.142 [− 0.009 + 0.286] and pain = − 0.166 [− 0.306 + 0.018]. Responsiveness: Anchor-based approach: AUC Δ400-point HA = 0.666 [0.583–0.749], AUC ΔQuickDASH = 0.556 [0.466–0.646]. MCID (optimal ROC curve cut-off): 6.07 for 400-point HA, − 2.27 for QuickDASH. MCID with mean response change + 12.034 ± 9.067 for 400-point HA and − 8.03 ± –9.7 for QuickDASH. The patient’s global impression of change was only correlated with the Δ400-point HA. Conclusions The 400-point HA standardised version has good psychometric properties. For responsiveness, we propose an MCID of at least 12.3/100. However, these results must be confirmed in other populations and pathologies. Trial registration This study was retrospectively registered into ISCTRN registry (Number ISRCTN25874481) the 07/02/2019.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?