Springer Nature
Browse

Patency of conduits in patients who received internal mammary artery, radial artery and saphenous vein grafts

Posted on 2020-03-24 - 04:56
Abstract Background Where each patient has all three conduits of internal mammary artery (IMA), saphenous vein graft (SVG) and radial artery (RA), most confounders affecting comparison between conduits can be mitigated. Additionally, since SVG progressively fails over time, restricting patient angiography to the late period only can mitigate against early SVG patency that may have occluded in the late period. Methods Research protocol driven conventional angiography was performed for patients with at least one of each conduit of IMA, RA and SVG and a minimum of 7 years postoperative. The primary analysis was perfect patency and secondary analysis was overall patency including angiographic evidence of conduit lumen irregularity from conduit atheroma. Multivariable generalized linear mixed model (GLMM) was used. Patency excluded occluded or “string sign” conduits. Perfect patency was present in patent grafts if there was no lumen irregularity. Results Fifty patients underwent coronary angiography at overall duration postoperative 13.1 ± 2.9, and age 74.3 ± 7.0 years. Of 196 anastomoses, IMA 62, RA 77 and SVG 57. Most IMA were to the left anterior descending territory and most RA and SVG were to the circumflex and right coronary territories. Perfect patency RA 92.2% was not different to IMA 96.8%, P = 0.309; and both were significantly better than SVG 17.5%, P < 0.001. Patency RA 93.5% was also not different to IMA 96.8%, P = 0.169, and both arterial conduits were significantly higher than SVG 82.5%, P = 0.029. Grafting according to coronary territory was not significant for perfect patency, P = 0.997 and patency P = 0.289. Coronary stenosis predicted perfect patency for RA only, P = 0.030 and for patency, RA, P = 0.007, and SVG, P = 0.032. When both arterial conduits were combined, perfect patency, P < 0.001, and patency, P = 0.017, were superior to SVG. Conclusions All but one patent internal mammary artery or radial artery grafts had perfect patency and had superior perfect patency and overall patency compared to saphenous vein grafts.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?