Posted on 2024-08-13 - 11:14
Abstract Background Maximal inspiratory pressure (MIP) is currently the most commonly used measure for respiratory muscle strength (RMS) estimation, however, requires significant effort. Falsely low values are therefore common, especially in fatigue-prone subjects, such as neuromuscular disorder patients. In contrast, sniff nasal inspiratory pressure (SNIP) requires a short, sharp sniff; this is a natural manoeuvre, decreasing required effort. Consequently, it has been suggested that use of SNIP could confirm the accuracy of MIP measurements. However, no recent guidelines regarding the optimal method of SNIP measurement exist, and varied approaches have been described. Objectives We compared SNIP values from three conditions, namely with 30, 60 or 90 s time intervals between repeats, the right (SNIPR) and left (SNIPL) nostril, and the contralateral nostril occluded (SNIPO) or non-occluded (SNIPNO). Additionally, we determined the optimal number of repeats for accurate SNIP measurement. Method 52 healthy subjects (23 males) were recruited for this study, of which a subset of 10 subjects (5 males) completed tests comparing the time interval between repeats. SNIP was measured from functional residual capacity via a probe in one nostril, while MIP was measured from residual volume. Results There was no significant difference in SNIP depending on the interval between repeats (P = 0.98); subjects preferred the 30 s. SNIPO was significantly higher than SNIPNO (P < 0.00001) but SNIPL and SNIPR did not significantly differ (P =  0.60). There was an initial learning effect for the first SNIP test; SNIP did not decline during 80 repeats (P =  0.64). Conclusions We conclude that SNIPO is a more reliable RMS indicator than SNIPNO, as there is reduced risk of RMS underestimation. Allowing subjects to choose which nostril to use is appropriate, as this did not significantly affect SNIP, but may increase ease of performance. We suggest that twenty repeats is sufficient to overcome any learning effect and that fatigue is unlikely after this number of repeats. We believe these results are important in aiding the accurate collection of SNIP reference value data in the healthy population.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?