Springer Nature
Browse

Accuracy and concordance of measurement methods to assess non-adherence after renal transplantation - a prospective study

Posted on 2020-04-01 - 04:32
Abstract Background Non-adherence (NA) to immunosuppressants (IS) among renal transplant recipients (RTRs) is associated with higher risk of allograft rejection, graft loss, and mortality. A precise measurement of NA is indispensable, although its prevalence differs greatly depending on the respective measurement methods. The objective of this study was to assess the accuracy and concordance of different measurement methods of NA in patients after renal transplantation. Design and methods This was a single-center prospective observational study. At baseline (T0), NA was measured via physicians’ estimates (PE), self-reports (SR), and tacrolimus trough level variability (CV%) in 78 RTRs. A Visual Analogue Scale (VAS, 0–100%) was applied both for SR and PE. In addition, we used BAASIS© for SR and a 5-point Likert scale for PE. NA was measured prospectively via electronic monitoring (EM, VAICA©) during a three month period. Meanwhile, all participants received phone calls in a two week interval (T1-T6) during which SRs were given. Results Seventy-eight RTRs participated in our study. At t0, NA rates of 6.4%, 28.6%, and 15.4% were found for PE, SR, and CV%, respectively. No correlation was found between these methods. During the study, the percentages of self-reported and electronically monitored adherence remained high, with a minimum mean of 91.2% for the strictest adherence measure (Timing Adherence ±30 min). Our results revealed a moderate to high association between SR and EM. In contrast to PE and CV%, SR significantly predicted electronically monitored adherence. Overall, a decreasing effect of electronically monitored adherence was found for both taking and timing adherence (±2 h, ±30 min) over the course of the study. Discussion The moderate to high concordance of SR and EM suggests that both methods measure NA equally accurately. SR seems to be a method that can adequately depict electronically monitored NA and may represent a good and economical instrument to assess NA in clinical practice. The increased adherence at the beginning of the study and its subsequent decrease suggests an intervention effect. Surveillance of IS intake via EM with intermittent phone calls could improve adherence on a short-term basis. To establish long-term effects, further research is necessary.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?