Springer Nature
Browse

A treatment planning study comparing IMRT techniques and cyber knife for stereotactic body radiotherapy of low-risk prostate carcinoma

Posted on 2019-08-10 - 04:42
Abstract Purpose Comparing radiation treatment plans by using the same safety margins and dose objectives for all techniques, to ascertain the optimal radiation technique for the stereotactic body radiotherapy (SBRT) of low-risk prostate cancer. Material and methods Treatment plans for 27 randomly selected patients were compared using intensity-modulated (IMRT) techniques as Sliding Window (SW), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT), as well as Cyber Knife (CK) system. The target dose was calculated to 36.25 Gy delivered in five fractions over 1 week. Dosimetric indices for target volume and organs at risk (OAR) as well as normal tissue complication probability (NTCP) of late rectal and urinary bladder toxicities were analyzed. Results The CK provided lower homogeneity in the target volume, but higher values for most of the conformity indices compared to the IMRT approaches. The SW demonstrated superior rectum sparing at medium-to-high dose range (V18 Gy - V32.6 Gy) compared to other techniques (p < 0.05). The whole urinary bladder experienced the best shielding by SW and VMAT at the medium dose (V18 Gy, p < 0.05 versus CK), however we obtained no relevant differences between techniques at the high dose. Generally, the CK demonstrated significantly superior rectum and bladder exposure at V18 Gy as compared to HT, SW, and VMAT. For the rectum, mean NTCP values were significantly superior for HT (NTCP = 2.3%, p < 0.05), and for urinary bladder, the NTCP showed no significant advantages for any technique. Conclusion No absolute dosimetric advantage was revealed to choose between CK or IMRT techniques for the SBRT of low-grade prostate cancer. Using the same safety margins and dose objectives, IMRT techniques demonstrated superior sparing of the rectum and bladder at a medium dose compared to CK. Comparing different IMRT approaches SW displayed superior rectum sparing at a medium-to-high dose range, whereas both SW and RA revealed superior bladder sparing compared to HT. HT demonstrated a significantly lower NTCP outcome compared to CK or IMRT techniques regarding the rectum. Radiation plans can be optimized further by an individual modification of dose objectives independent of the treatment plan strategy.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?