Springer Nature
Browse

A comparative assessment of clinical efficiency between premium heat-activated copper nickel-titanium and superelastic nickel-titanium archwires during initial orthodontic alignment in adolescents: a randomized clinical trial

Posted on 2019-12-16 - 06:26
Abstract Background To compare the clinical efficiency of premium heat-activated copper nickel-titanium (Tanzo Cu-NiTi) and NT3 superelastic NiTi during initial orthodontic alignment. Subject and methods A total of 50 patients were randomly allocated to 1 of 2 different archwire types (group 1, Tanzo Cu-NiTi; group 2, NT3 superelastic NiTi). Eligibility criteria included Class I or Class II malocclusion, moderate maxillary anterior crowding, and healthy periodontal condition. Impressions of the upper arches were taken before archwire placement (T0) and at every 4 weeks (T1, T2, T3, and T4). For T1 and T2 stages, 0.014-in., and for T3 and T4 stages, 0.018-in. archwires were used. The primary outcome was the alignment efficiency assessed using Little’s irregularity index. The secondary outcomes were arch width and incisor inclination changes. Data were analyzed using independent samples t test, repeated measures ANOVA, and Mann-Whitney U test. Marginal models were established for the estimation of coefficients. Results The anterior irregularity index reduction was mostly observed between T0 and T2 periods, which were respectively − 7.40 ± 0.50 mm (p < 0.001; 95% CI, − 8.94, − 5.85) and − 6.80 ± 0.55 mm (p < 0.001; 95% CI, − 8.49, − 5.12) for groups 1 and 2 (p < 0.001). With both wires, Little’s irregularity index decreased over time, and the difference between the groups was not significant (p = 0.581; estimated effect size, 0.011). No statistically significant difference was found between the groups in terms of intercanine and intermolar width and incisor inclination changes. Conclusion There were no significant between-group differences in alignment efficiency, arch width, and incisor inclination change. There was an increased alignment with 0.014-in. compared with 0.018-in. diameter archwire.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?